Cured Concrete Foundation Walls
Specify the surface condition, wall joints, top termination and protection or drainage before backfill.
Oseaguard self-adhesive HDPE geomembrane combines a polyethylene barrier, factory-applied adhesive and a removable release liner. For installation onto a prepared substrate, confirm the adhesion requirements and specify how laps, corners and penetrations will be sealed.
The Chinese LOCA-110 product sheet lists the dimensions below for that model. Request the export roll specification and confirm whether the quoted thickness refers to the complete sheet or to the HDPE layer.
| Property | Product reference |
|---|---|
| Construction | HDPE barrier, factory-applied adhesive and removable release liner |
| LOCA-110 listed membrane thickness | 1.2, 1.5 and 1.7 mm |
| LOCA-110 listed roll dimensions | 1.0 or 2.0 m nominal width × 20 m nominal length |
| LOCA-110 lap reference | Factory self-adhesive long edges and designated tape for end laps, per its Chinese product instructions |
| Substrate and preparation | Confirm substrate condition, moisture limits, primer if required and adhesive compatibility |
| Documents to request | Grade-specific thickness basis, substrate adhesion data and lap, termination and penetration details |
The LOCA-110 values are Chinese model references. Confirm roll dimensions, accessory system and applicable test results for the grade quoted for export.
For a post-applied wall, the adhesive must bond to the prepared existing substrate. A pre-applied system is installed before concrete placement and must be documented for bonding to fresh concrete. Oseaguard’s Chinese LOCA-102 is a separate pre-applied example. Indicate the pour sequence and bonding surface when requesting a quote.
Ask for the full assembly when access is limited or when the waterproofing needs to continue around several details.
Specify the surface condition, wall joints, top termination and protection or drainage before backfill.
Share drawings of corners and penetrations. Confirm the bonding surface, seam treatment and accessories for the selected build-up.
Identify which membrane is installed before the pour and which is bonded afterward. Request the documented connection between them.
For a membrane installed before casting, select a documented pre-applied grade with fresh-concrete bonding and matching accessories. Submit the slab and wall junction detail for review.
Lap treatment depends on the system. LOCA-110's Chinese instructions describe cold-bonded laps with specific edge and tape details. Confirm the method for the quoted grade.
The adhesive provides bond. Where drainage and protection are specified, include separate layers or an approved drainage and protection assembly in the design.
Select HDPE geomembrane in the form and include Self-Adhesive HDPE Geomembrane in your project details. Send the following information with your request.